產品中心 > 醫(yī)療設備質量控制檢測設備 > MRI磁共振質量檢測裝置 > (MRI)磁共振性能檢測模體SMR170
  • (MRI)磁共振性能檢測模體SMR170

  • 產品編號:11975
  • 產品名稱:(MRI)磁共振性能檢測模體
  • 產品型號:SMR170
  • 訂貨編號:
  • 市 場 價:
  • 促 銷 價:
  • 狀    態(tài):
  • 產    地:
  • 簡要參數(shù):
    磁共振性能檢測模體,丙烯酸材料的圓柱形模體和球形模體,內徑20cm,模體內部加注硫酸銅溶液,檢測空間分辨率(高分辨率)、密度分辨率(低對比度)、測信躁比、T1,T2值、幾何線性等參數(shù)。 SMR170模體包括20cm的圓柱形殼體、10cm的立方體試塊
  • 人    氣:2647

相關推送

產品介紹

Magphan® Phantoms are designed to perform a wide range of precision performance evaluations of Magnetic Resonance Imaging (MRI) Scanners.
未標題-1.jpg
 The design criteria for the Magphan® phantoms are based on physicist, Dr. David Goodenough's extensive experience with MRI system evaluation and his well documented research into the quantification of image system performance tests. The test objects that make up the current Magphan® models embody two decades of scientific evaluation and field experience.

The Magphan®'s patented spherical design combines precise alignment of spherical geometry with cubic geometry. As magnetic field characteristics are mapped according to spherical harmonics, natural magnetic fields extend to diagonally symmetric volumes (DSVs), or spheres. This symmetry is the reason the AAPM Task Group's Report number 6a, titled "Acceptance Testing of Magnetic Resonance Imaging Systems," stated, "The sperical shape is recommended for reasons of symmetry." Imaging performance is evaluated in the transaxial, coronal, sagittal and oblique planes by rotating the sphere.

未標題-2.jpg



 The Magphan® is also available with a conventional cylindrical housing for test groups and manufacturers who prefer the conventional cylindrical shaped phantoms.

Spherical Magphan® (SMR100) is a urethane sphere composed of two hemispherical shells with an inner diameter of 20cm.未標題-3.jpg

The shells are connected with a simple threaded flange connecting ring. The test cube assembly can be quickly removed without tools for greater imaging flexibility and easy access for cleaning and maintenance.
Cylindrical Magphan® (SMR170) has a removable end plate for internal access. The acrylic cylinder has an outer diameter of 20cm and an inner diameter of 19cm.
Tests - Summary

  • spatial uniformity

  • signal-to-noise ratio (SNR)

  • spherical geometry

  • in-vitro sample testing

  • geometric distortion (spatial linearity)

  • pixel (matrix) size verification

  • scan slice width and contiguity

  • verification of patient alignment system

  • spatial resolution up to 11 line pairs per cm (0.45mm resolution)

  • low contrast sensitivity

  • T1 and T2 measurements

  • evaluation of 3-dimensional volume reconstruction

 

Stock #Description
SMR100Magphan® 100 including 20cm spherical housing,
10cm test cube and case
SMR140Magphan® 140 - 10cm sphere with support disk
SMR170Magphan® 170 including 20cm cylindrical housing,
10cm test cube and case
SMR172Magphan® 172 including 20cm spherical housing,
20cm cylindrical housing, 10cm test cube and cases.

 未標題-4.jpg